Description
LAQUAact EC110 Handheld Conductivity/TDS/Res/Temp Meter
Model: EC110
Horiba – Japan
Features:
- Automatic and manual conductivity calibration up to 4 points
 - Adjustable reference temperature and temperature coefficient
 - Selectable cell constant and measurement unit
 - Automatic / Manual temperature compensation and temperature calibration function
 - Conductivity and total dissolved solids (TDS) conversion
 - Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl
 - Built-in memory can store up to 100 data
 - Auto shut-off (programmable: 1 to 30 minutes)
 - Auto-Hold / Auto-Stable measurement
 - Large LCD: 52mm x 64mm
 - Powered by 2 x AAA batteries (LR03) or Ni-MH rechargeable batteries or power adaptor
 - Casing is IP67 waterproof (for 30mins immersion in 1m depth of water) and dustproof
 - Packaged in new molded carry case
 - 01 year meter warranty
 
Meter Kit Available:
EC110-K

- LAQUAact EC110 Conductivity/TDS/Res/Temp meter, built-in electrode holder, 2 x AAA batteries
 - Instruction manual
 - 9382-10D plastic-body, Titanium/Platinum black conductivity probe (k=1.0) with integrated temprature sensor
 - 84 uS/cm, 1413 uS/cm, 12.88 mS/cm, 111.8 mS/cm conductivity standard solutions (60ml each)
 - Carry case
 
Specifications:
| Model | LAQUAact EC110
 Conductivity/TDS/Res/Temp  | 
|---|---|
| Condutivity Range | …µS/cm to 2000 mS/cm | 
| Resolution | 0.05% F.S. | 
| Accuracy | ±0.6% F.S.; ±1.5% F.S. > 18.0 mS/cm | 
| Reference Temperature | 15 to 30.0°C (adjustable) | 
| Temperature Coefficient | 0.0 to 10.0% (adjustable) | 
| Cell Constant | 0.1, 1.0, 10.0 (selectable) | 
| Measurement Unit | μS/cm, mS/cm, S/m (selectable / auto-ranging) | 
| Calibration Points | Up to 4 (Auto/Manual) | 
| TDS Range | …ppm to 1000 ppt (TDS factor=0.5) | 
| Resolution | 0.01 ppm / 0.1 ppt | 
| Accuracy | ±0.1% F.S. | 
| Calibration Curves | EN27888, 442, Linear, NaCl | 
| Resistivity Range | 0.000 Ω•cm to 200.0 MΩ•cm | 
| Resolution | 0.05% F.S. | 
| Accuracy | ±0.6% F.S.; ±1.5% F.S. > 18.0 MΩ•cm | 
| Temperature Range | -30.0 to 130.0°C | 
| Resolution | 0.1°C | 
| Accuracy | ± 0.4°C | 
| Calibration Option | Yes | 
| Memory Data | 100 | 
| Auto-Shut Off | Yes (Programmable: 1 to 30 minutes) | 
| Auto-Hold / Auto-Stable | Yes | 
| Cell Constant Display | Yes | 
| Electrode Status | On screen display | 
| Diagnostic Messages | Yes | 
| Display | Custom LCD | 
| Inputs | BNC, phono, DC sockets | 
| IP Rating | IP67, shock-resistant | 
| Power Requirements | 2 x AAA (LR03) or Ni-MH rechargeable batteries or power adaptor | 
| Battery Life | >200 hours | 


				
				
				
				
Reviews