LAQUA PC1100 Benchtop pH Meter – Water Quality Meters
Model: PC1000
Horiba – Japan
Features:
- Dual channel / display
 - Automatic pH calibration up to 5 points using NIST, USA, or Custom pH buffers
 - Switchable pH resolution – 0.1, 0.01, 0.001 pH
 - Offset and slope display
 - Automatic / Manual temperature compensation and temperature calibration function
 - Automatic and manual conductivity calibration up to 4 points
 - Adjustable reference temperature and temperature coefficient
 - Selectable cell constant and measurement unit
 - Conductivity and total dissolved solids (TDS) conversion
 - Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl
 - Two (2) salinity calibration curves: NaCl, Seawater
 - Auto log data; Built-in memory can store up to 1000 data
 - Real-time clock and date / time stamp
 - Auto shut-off (programmable: 1 to 30 minutes)
 - Auto-Hold / Auto-Stable measurement
 - Calibration alarm (programmable: 1 to 400 days)
 - Custom black and white static LCD
 - RS232 and USB output for connecting to computer or printer
 - Security (password setting)
 - 01 years meter warranty
 
Meter Kit Available:
PC1100-S
Package Details:
- LAQUA PC1100 Dual Channel pH/ORP/Cond/TDS/Res/Sal/Temp custom black and white static LCD meter
 - Protection cover, integrated electrode stand, power adaptor with 6 plugs (US, EU, UK, ANZ, China, Korea)
 - 9615S-10D ToupH glass-body, refillable pH electrode with integrated temperature sensor
 - 9382-10D plastic-body, Titanium/Platinum black, conductivity probe (k=1.0) with integrated temperature sensor
 - 502-S: pH 4.0 / 7.00 / 10.01 buffers & 3.33M KCl (250ml each)
 - 503-S: 84 µS/cm, 1413µS/cm, 12.88 mS/cm, 111.8 mS/cm conductivity solutions (250ml each)
 - Instruction manual
 
PC1100-SN: Kit with 501-S (pH 4.01 / 6.86 / 9.18 NIST buffers & 3.33M KCl, 250ml each) is available upon request.
Specifications:
| Model | LAQUA PC1100
 Dual Channel pH/ORP/Cond/TDS/Res/Sal/Temp  | 
|---|---|
| pH Range | -2.000 to 20.000 pH | 
| Resolution | 0.1, 0.01, 0.001 pH | 
| Accuracy | ± 0.003 pH | 
| Calibration Points | Up to 5 | 
| Buffer Options | USA, NIST, Custom | 
| ORP Range | ± 2000 mV | 
| Resolution | 0.1 mV | 
| Accuracy | ± 0.2 mV | 
| Conductivity Range | …µS/cm to 2000 mS/cm | 
| Resolution | 0.05% F.S. | 
| Accuracy | ±0.6% F.S.; ±1.5% F.S. > 18.0 mS/cm | 
| Reference Temperature | 15 to 30°C (adjustable) | 
| Temperature Coefficient | 0.00 to 10.00% (adjustable) | 
| Cell Constant | 0.1, 1.0, 10.0 (selectable) | 
| Measurement Unit | μS/cm, mS/cm, S/m (selectable / auto-ranging) | 
| Calibration Points | Up to 4 (Auto / Manual) | 
| TDS Range | 0.01 mg/L to 1000 g/L | 
| Resolution | 0.01 mg/L | 
| Accuracy | ±0.1% F.S. | 
| Calibration Curves | EN27888, 442, Linear (0.40 to 1.00), NaCl | 
| Resistivity Range | 0.00 Ω•cm to 200.0 MΩ•cm | 
| Resolution | 0.05% F.S. | 
| Accuracy | ±0.6% F.S.; ±1.5% F.S. > 1.80 MΩ•cm | 
| Salinity Range | 0.00 to 100.00 ppt / 0.000 to 10.000 % | 
| Resolution | 0.01 ppt / 0.001 % | 
| Accuracy | ±0.2% F.S. | 
| Calibration Curves | NaCl / Seawater | 
| Temperature Range | -30.0 to 130.0°C | 
| Resolution | 0.1°C | 
| Accuracy | ±0.4°C | 
| Calibration Option | Yes | 
| Memory Data | 999 | 
| Auto Log Data | Yes | 
| Real-time Clock | Yes | 
| Date / Time Stamp | Yes | 
| Auto-Shut Off | Yes (Programmable: 1 to 30 minutes) | 
| Auto-Hold / Auto-Stable | Yes | 
| Offset / Slope Display | Yes (Independent acid and alkaline slopes depending on calibration) | 
| Electrode Status | On screen display | 
| Diagnostic Messages | Yes | 
| Calibration Alarm | Yes (Programmable: 1 to 400 days) | 
| Display | Custom black and white static LCD, Dual Channel | 
| Inputs | Dual BNC, dual phono, DC sockets | 
| Output | RS232, USB | 
| Power Requirement | AC adaptor, 100-240V, 50/60Hz | 
| Weight | 500g | 
| Dimensions | 170(L) x 174(D) x 73(H) mm | 



				
				
				
				