BT-9300S Laser Particle Size Analyzer

Application

  • Non-metal powder: calcium carbonate, talcum powder, kaolin, zirconium silicate, wollastonite, graphite, konilite , tourmaline, mica, barite, gypsum, bentonite, diamond, quartz, diatomite, feldspar, tremolite, clay, garnet, vermiculite, titanium pigment, etc.
  • Metal powder: aluminum powder, iron powder, magnesium powder, molybdenum powder, copper powder, zinc powder, rare metal powder and various alloy powders etc.
  • Other powders: pharmaceutical, pesticide, abrasive, food, cement, ceramics, soil, pigment, powders used in scientific research & teaching, oil exploration, geological analysis, the river sediment, electronic materials, chemical materials, military materials, battery materials, various emulsion, coating, etc.

Share this product

Description

BT-9300S Laser Particle Size Analyzer

Brand: Bettersize – China

 

 

BT-9300S laser particle size analyzer is a kind of instrument which has functions of automatic alignment, automatic water supply, automatic water level sensor and adjustable circulation flow, higher automation, easier operation and better performance. It adopts high quality semiconductor laser which has high power, long service life and good monochromaticity. By adopting a specially designed large size and high sensitivityphotoelectric detector array which manufactured by large scale integrated circuit technology; using two ways of sample inflow: centrifugal circulating pump and small volume cell; using the Mie theory and data processing mode with various distribution models; adopting various advanced technology and manufacturing process, such as high precision data transmission and processing circuit, thus the instrument has characteristics of accuracy, reliability, rapid test, good repeatability, simple operation etc, is a new generation of particle size analyzer that sets laser technology, computer technology and optoelectronic technology in one. Especially applicable to the laboratory in enterprises, universities, research institutes, etc.

Technical Specification

  1. Size Range: 0.1-716 um
  2. Sample Inflow Method: External semi-automatic circulating and dispersing system
  3. Repeatability: <1% (CRM D50)
  4. Accuracy: <1% (CRM D50)
  5. Measuring Principle: Mie scattering theory
  6. Laser: optical fiber semiconductor laser
  7. Operation System: Win XP/ Win 7
  8. Connection Port: USB or RS232
  9. Photodetector: 84
  10. Ultrasonic Power: 50 W
  11. Tank Capacity: 500 ml
  12. Circulating Flowrate: 500-2500 ml / min
  13. Agitating Speed: 500-2500 rpm
  14. Small Volume Cell Capacity: 20 ml(optional)
  15. Small Volume Cell Agitating Speed: 120 rpm(optional)
  16. Voltage: 220V, 50/60 Hz
  17. Outer Dimension: 720*300*280mm

Application

  • Non-metal powder: calcium carbonate, talcum powder, kaolin, zirconium silicate, wollastonite, graphite, konilite , tourmaline, mica, barite, gypsum, bentonite, diamond, quartz, diatomite, feldspar, tremolite, clay, garnet, vermiculite, titanium pigment, etc.
  • Metal powder: aluminum powder, iron powder, magnesium powder, molybdenum powder, copper powder, zinc powder, rare metal powder and various alloy powders etc.
  • Other powders: pharmaceutical, pesticide, abrasive, food, cement, ceramics, soil, pigment, powders used in scientific research & teaching, oil exploration, geological analysis, the river sediment, electronic materials, chemical materials, military materials, battery materials, various emulsion, coating, etc.

Features

  1. By adopting advanced forming process, the instrument has compact structure, beautiful appearance and easy maintenance; by using the latest anti-interference technology, the instrument has better electrical stability and lower failure rate.
  2. Calibration accuracy : all instruments are passed calibration based on the standard sample, which fully guarantee the accuracy of the instrument’s test results. At the same time, the standard sample is provided along with the instrument, users can check the accuracy of the instrument at any time, avoid any losses brought by inaccurate results which are caused by drifting of the instrument, voltage fluctuation etc.
  3. Two sample inflow ways: small volume cell and circulating pump; circulating pump is suitable for samples whose medium is water; small volume cell is suitable for samples whose medium is organic solvent. Thetwo ways can be switched conveniently and quickly.
  4. Uniquely designed automatic circulating & dispersing system. The system includes the ultrasonic disperser (which can run with empty cup), flow adjustable centrifugal circulating pump, electronic water level sensor, automatic water supply control system, automatic drainage control system, etc. Large capacity (500 ml) of flow tank guarantees the representativeness of samples. Full stainless steel casing makes the system durable in use. Circulating system is suitable for water medium.
  5. Unique small volume cell system: the system includes 20ml small volume cell and vertical electric mixer (Bettersize patent). It is ideal for organic solvent to be medium and precious samples. The most important thing is that the small volume cell system and circulating system can be switched conveniently (Bettersize patent).
  6. 3-D automatic focusing system consists of precision hybrid stepping motor, precision guide rail, lead screw, connecting axle and subdivision controller, whose minimum step is 1.3 micron, which ensures focus of laser beam is always on the center of detector, thus improves the accuracy of the test results.
  7. Powerful software, friendly interface and easy operation, it has multiple languages, which can be easily switched; the test results can be converted into Excel, word or graphic format; test report can be freely edited, can easily add user’s information to test report; system stores hundreds of optical parameters of material, almost covers all common samples, ensure that test results are accurate and reliable; report has English and Chinese version, total 14 formats, which can be chosen at any time.

Reviews

There are no reviews yet.

Be the first to review “BT-9300S Laser Particle Size Analyzer”

This site uses Akismet to reduce spam. Learn how your comment data is processed.